ANTSPACE HK3 Introduction

Specification details for ANTSPACE HK3
| Product Overview | Value | |||
| Version | ANTSPACE HK3 | |||
| Dimensions (L*W*H) (mm) | 6058*2438*2896 | |||
| Miner Capacity | 210 units -S19 Hyd. Series miner | |||
| Container Certification | China Classification Society Certification | |||
| Safety Certification |
North America/Standards:NFPA 79:2021,UL 508A:2018 R8.21, CSA C22.2 No. 14-18,ANSI/ISO 12100:2012 |
|||
| Operating Power(kW) | 1047~1050 | |||
| PUE(Power Usage Effectiveness) | 1.022(Excluding cooling tower)/1.036(Including cooling tower) | |||
| Input Voltage and Frequency | 415V±5% 60Hz(North America) 400V±5% 50Hz(EU、Middle East) |
|||
| Detailed Characteristics | Value | |||
| Shipping Weight(T) | 8 | |||
| Operating Weight (T) | 12 | |||
| Main Switch of Power Distribution Cabinets(A) | 1200(North America) 1250(EU、Middle East) |
|||
| Rated Current(A) | 952 | |||
| Standard Power(kW) | 1049 | |||
| Maximum Power(kW) | 1050 | |||
| Rated Current per Miner(A) | 10 | |||
| Inlet Cable | The inlet cables can withstand high-voltage of above 600V, with the following requirements per phase: L1 single core cable 600kcMil(300mm²)x4 L2 single core cable 600kcMil(300mm²)x4 L3 single core cable 600kcMil(300mm²)x4 N Single-core cable 600kcMil(300mm²)x4 PE single-core cable 500kcMil(240mm²)x2 |
|||
| Connection Interface(Cooling Tower) | DN125(GB/T 9119-2010 PN16 DN125) | |||
| Connection Interface(Plate Heat Exchage Interface) | DN100(GB/T 9119-2010 PN16 DN100) | |||
| Flow Rate(m³/h) | >85 | |||
| Quantity of ANTSPACE powered by one 2500kVA Transformer | 2 | |||
Specification details for Dry-Wet Towers
One of the following two Dry-Wet Towers can be chosen based on the personalized demand.
| Product Overview | Value | |||
| Type | Dry-Wet Tower Traditional Type (DWT-T) | Dry-Wet Tower Container Type (DWT-C) | ||
| Dimensions(L*W*H)(mm) | 5800*2240*4200 | 6058*2438*2896 | ||
| Heat Dissipation Capacity(kW) | 1000 | 1000 | ||
| Outlet Temperature @ 28℃ Wet Bulb Temperature | 35℃ | 35℃ | ||
| Container Certification | None | China Classification Society Certification | ||
| Safety Certification | North America/Standards: NFPA 79:2021, UL 508A:2018 R8.21, CSA C22.2 No. 14-18, ANSI/ISO 12100:2012 EU Standards: EN ISO 12100, EN 60204-1 |
North America/Standards: NFPA 79:2021, UL 508A:2018 R8.21, CSA C22.2 No. 14-18, ANSI/ISO 12100:2012 EU Standards: EN ISO 12100, EN 60204-1 |
||
| Operating Power(kW) | 14~28 | 14~28 | ||
| Motor Rated Voltage and Frequency | 415V±5% 60Hz(North America) 400V±5% 50Hz(EU、Middle East) |
415V±5% 60Hz(North America) 400V±5% 50Hz(EU、Middle East) |
||
| Detailed Characteristics | Value | |||
| Shipping Weight(T) | 5 | 6 | ||
| Operating Weight(T) | 9 | 10 | ||
| Connection Interface(Container) | DN125(GB/T 9119-2010 PN16 DN125) | DN125(GB/T 9119-2010 PN16 DN125) | ||
| Water Resupply Pipe Interface | DN40(Internal thread) | DN40(Internal thread) | ||
| Drain Pipe Interface | DN65(Internal thread) | DN65(Internal thread) | ||
| Noise Level @25℃, 16m | 70dBA | 70dBA | ||
| Water Consumption(m³/h) | 1~1.5 | 1~1.5 | ||
Environmental Requirements:
|
Environmental Requirements
|
||||
| 1 | Cooling tower is required to be placed on flat ground, horizontal degree (±1 degree). | |||
| 2 | The ground surfaced is required to be hardened and stable, able to withstand at least 14-ton load. | |||
| 3 | A 10-ton crane is needed for unloading ANTSPACE and cooling tower. | |||
| 4 | Add-on items such as stairs, transformers, cables, bridge racks and cable distribution boxes are not included in the delivery of ANTSPACE. BITMAIN team can provide design suggestions if needed. | |||
| 5 | Client needs to confirm the opening directon of container and it needs to face air-intake. Door on left is current design by defult. | |||
| 6 | Keep at least 2 meters of air in-take space around the cooling tower. | |||
| 7 | Altitude: ≤3000m. If the altitude is higher than 1000-meter, transformer and switch should be derated, the total power of ANTSPACE must be decreased by 1% for each elevation increment of 100 meters. | |||
| 8 | Operating temperature: -25°C to 40°C. Operating humidity: 10%RH to 90%RH. When the initial coolant temperature is below 20 °C, the internal circulation should be turned on to heat up the coolant to above 20 °C before starting the mining machine. | |||
| 9 | When the ambient temperature is below 5 ℃, the cooling tower can be switched to cold-dry mode. | |||
| 10 | Choose pure water or suitable antifreeze as coolant based on local climate conditions. | |||
| 11 | The suitable ambient temperature for ANTSPACE does not represent the suitable ambient temperature for mining machine. | |||